Monoline Single Pair Balun - RJ45 pin 4 and 5 Jack to RJ45 Jack 10BaseT from NetConnex. The unique Monoline Baluns, only from ETS, allow you to reuse existing premise cabling the Ethernet 10BaseT networks. One single pair of UTP or STP replaces two pair UTP with improved NEXT (near end crosstalk) over the 802. - May use installed base of telco/Cat3 or better UTP
- The Cable Doubler allows 1 existing run to a workstation to support two connections without rewiring.
- Exceeds 802.3 10BaseT NEXT specification, isolating the reciever from the transmitted signal
- Run 100 meters (TIA568A) on high quality telco, Cat3 or better UTP
- Compact plastic case
- Made in USA. 100% QA.

|
Description:
Monoline Single Pair Balun - RJ11 pins 3 and 4 jack to RJ45 Jack - 10BaseT from NetConnex. The unique Monoline Baluns, only from ETS, allow you to reuse existing premise cabling the Ethernet 10BaseT networks. One single pair of UTP or STP replaces two pair UTP with improved NEXT (near end crosstalk) over the 802. - May use installed base of telco/Cat3 or better UTP
- The Cable Doubler allows 1 existing run to a workstation to support two connections without rewiring.
- Exceeds 802.3 10BaseT NEXT specification, isolating the reciever from the transmitted signal
- Run 100 meters (TIA568A) on high quality telco, Cat3 or better UTP
- Compact plastic case
- Made in USA. 100% QA.

|
Description:
Monoline Single Pair Balun - RJ45 3 cord pins 4 5 to RJ45 jack 10BaseT from NetConnex. The unique Monoline Baluns, only from ETS, allow you to reuse existing premise cabling the Ethernet 10BaseT networks. One single pair of UTP or STP replaces two pair UTP with improved NEXT (near end crosstalk) over the 802. - May use installed base of telco/Cat3 or better UTP
- The Cable Doubler allows 1 existing run to a workstation to support two connections without rewiring.
- Exceeds 802.3 10BaseT NEXT specification, isolating the reciever from the transmitted signal
- Run 100 meters (TIA568A) on high quality telco, Cat3 or better UTP
- Compact plastic case
- Made in USA. 100% QA.

|
Description:
Monoline Single Pair Balun - RJ11 3 cord pins 3 4 to RJ45 jack 10BaseT from NetConnex. The unique Monoline Baluns, only from ETS, allow you to reuse existing premise cabling the Ethernet 10BaseT networks. One single pair of UTP or STP replaces two pair UTP with improved NEXT (near end crosstalk) over the 802. - May use installed base of telco/Cat3 or better UTP
- The Cable Doubler allows 1 existing run to a workstation to support two connections without rewiring.
- Exceeds 802.3 10BaseT NEXT specification, isolating the reciever from the transmitted signal
- Run 100 meters (TIA568A) on high quality telco, Cat3 or better UTP
- Compact plastic case
- Made in USA. 100% QA.

|
Description:
Gigabit Ethernet Cable Clamp - Common Mode Noise Tester from NetConnex. ETS announces the availability of the CC-101, a cable clamp for injecting common mode current into a Cat5 cable in order to test gigabit Ethernet for common mode noise. - Input 50 ohm female BNC
- Return Loss Guaranteed to exceed 30 dB
- Output 50 ohm female NC (requires 1% 50 ohm load)
- Cable aperture 1/4" copper tube
- Assembly 6 Allen head screws
- Release screws, remove top, insert wire per IEEE 802.3 1000BaseT document, replace top, and reapply screws.
- NoteIt is important to properly tighten screws to assure continuous contact between the two halves of the copper tubing.

|